Aluminum Long Weld Neck Flanges
Section shape: flange ring with straight hub and butt-weld end
Alloy and temper: 6061-T6, 3003-H112, 5083-H112 / H116, per mill test certificate
Standard: ASME B16.5 flange end; ASME B31.3 Appendix L rating basis; EN 1092-4 for the PN series
Technique: forging plus CNC machining, ASTM B247/B247M forging form
Surface treatment: natural finish, clear anodizing, or as specified
Outside diameter: per ASME B16.5 flange end for the size and class
Hub length: 229 mm through-hub up to NPS 4, 305 mm above NPS 4, or to drawing
Bore: weld neck flange B dimension by default, or to drawing
MOQ: flexible; small trial orders and full containers both accepted
Lead time: 15-30 days
Certificate: EN 10204 3.1, with 3.2 and third-party inspection available
HS code: 7609, subject to final classification by destination customs
Transport package: export crate, facing protected, sealed against moisture
Customer service is online. Enter the chat to get the latest quotation.
Spot stock
Customize
Factory direct sale
7 days delivery
GNEE has supplied aluminum long weld neck flanges since 2008 and exports to more than 100 countries and regions. Each flange is machined in one piece from an aluminum forging, with an aluminum flange end and an aluminum hub, in 6061, 3003 or 5083.
The long hub moves the butt weld away from the gasket face and gives the nozzle a stress transition into the shell. That makes this flange type common on pressure vessel nozzles, columns, heat exchanger channels and instrument connections. Aluminum is selected where corrosion resistance, lower weight or low-temperature service governs the material choice.
Supply covers NPS 1/2 to 24 (DN15 to DN600) and drawing-based sizes, with ASME B16.5 flange-end dimensions and an ASME B31.3 Appendix L rating basis.
Send the drawing and service conditions for a quotation and technical confirmation within 24 hours.
What is Aluminum Long Weld Neck Flange
A long weld neck flange is a flange ring with an extended straight hub that is butt welded to the pipe or nozzle. ASME B16.5-2020 names this form a straight hub welding flange in section 2.8. The flange end carries the outside diameter, thickness, facing and drilling of the same size and class of weld neck flange, while the hub extends the weld away from the gasket face.
The extra hub length leaves room for radiographic or ultrasonic examination of the butt weld and spreads pipe bending into the flange plate over a longer path. On nozzles that see cyclic load, temperature change or a tight sealing requirement, that geometry is the reason this flange type is specified.
Service positions include pressure vessel nozzles, column nozzles, heat exchanger channel and shell connections, tank outlets, and instrument or level-gauge branches. Hub length on these positions is usually set by the equipment drawing, which is why drawing-based manufacture is the normal route for an aluminum LWN.
Types of Aluminum Long Weld Neck Flanges

Specification of Aluminum Long Weld Neck Flanges
| Item | Detail |
|---|---|
| Flange form | Long weld neck, straight hub welding flange per ASME B16.5 section 2.8 |
| Flange end standard | ASME B16.5, same size and class weld neck flange tables |
| Hub standard | ASME B16.5 section 2.8 default rules, or equipment drawing and agreement |
| Rating basis | ASME B31.3 Appendix L for aluminum flanges; EN 1092-4 for the PN series |
| Size range | NPS 1/2 to 24 (DN15 to DN600), or to drawing |
| Class | Class 150, 300 and 600 in the ASME system |
| Facing | Raised face or flat face |
| End form | Square-cut by default; weld bevel to drawing |
| Material form | Forging per ASTM B247/B247M; plate-cut flanges per ASTM B209 when specified |
| Certificate | EN 10204 3.1, with 3.2 and third-party inspection available |
| HS code | 7609, subject to final classification by destination customs |
| MOQ and lead time | MOQ flexible, small and large orders both accepted; 15-30 days |
Read More About : Aluminum Flange

How to Check Aluminum Long Weld Neck Flange Dimensions
Buyers comparing long weld neck flange dimensions are usually checking two groups at once. The flange end is standardised and decides whether the part mates to the equipment. The hub is the drawing-driven part and decides whether the nozzle reinforcement and butt weld can be completed.
| Dimension group | Items | Usual source |
|---|---|---|
| Flange end | Outside diameter, thickness, bolt circle, bolt hole size and count, facing | ASME B16.5 weld neck flange table for the same size and class, or equipment drawing |
| Hub | Overall length H from the facing, large-end and small-end outside diameters, wall thickness, bore B, end form | Equipment drawing or agreement |
| Bore | Same B dimension as the weld neck flange of the same size and class by default | Section 2.8 default or agreement |
This table groups the dimensions used in drawing-based manufacture. It is a checklist for inquiry review, not an ASME B16.5 size table. Flange-end values come from the weld neck flange tables of the same class, and hub values follow the customer drawing and agreement.
Aluminum Long Weld Neck Flange Standard Dimensions: ASME B16.5 the Section 2.8 Rules
The phrase long weld neck flange standard dimensions is best read as a combination: the flange end follows the B16.5 tables and the hub follows the section 2.8 default rules. B16.5 does not publish a separate size table for this flange form. The defaults are set out below for comparison.
| Item | Section 2.8 default | Note |
|---|---|---|
| Hub wall | Equal thickness | The straight hub form |
| Hub diameter | Hub base diameter X of the weld neck flange of the same size and class | Flange-end values come from the B16.5 weld neck flange tables |
| Through-hub length | 229 mm (9 in) up to NPS 4; 305 mm (12 in) above NPS 4 | Other lengths are agreed between the end user and the manufacturer |
| Bore | B dimension of the weld neck flange of the same size and class | A changed bore is subject to agreement and stays within the lap joint flange bore limit |
| End | Square cut | A weld bevel is prepared when required, commonly 37.5 degrees |
A 406 mm (16 in) hub appears in some manufacturer catalogues as a working convention. It is a custom reference, not a B16.5 default value. Confirm all hub dimensions against the customer drawing and agreement.
| Hub form | Bore characteristic | Status |
|---|---|---|
| Standard hub | Bore equal to the nominal size | Matches the section 2.8 default |
| Heavy barrel | Extra hub thickness for integral reinforcement, removing the need for a reinforcing pad | Custom or agreed form |
| Equal barrel | Bore set to the pipe schedule for a butt weld to the same pipe size | Custom or agreed form |
Chemical Composition of Aluminum Long Weld Neck Flange Alloys
Composition is confirmed against the melt and lot on the mill test certificate. The typical limits for the three supplied alloys are listed below; the certificate governs the delivered flange.
| Alloy | Si | Fe | Cu | Mn | Mg | Cr | Zn | Ti | Other, each | Al |
|---|---|---|---|---|---|---|---|---|---|---|
| 6061 | 0.40-0.80 | 0.70 max | 0.15-0.40 | 0.15 max | 0.80-1.20 | 0.04-0.35 | 0.25 max | 0.15 max | 0.05 max | Remainder |
| 3003 | 0.60 max | 0.70 max | 0.05-0.20 | 1.00-1.50 | 0.03 max | - | 0.10 max | 0.05 max | 0.05 max | Remainder |
| 5083 | 0.40 max | 0.40 max | 0.10 max | 0.40-1.00 | 4.00-4.90 | 0.05-0.25 | 0.25 max | 0.15 max | 0.05 max | Remainder |
Composition in weight percent, typical registered limits for the wrought alloys. Values for the delivered lot are those on the EN 10204 3.1 certificate.
Mechanical Properties of Aluminum Long Weld Neck Flange Grades
Temper is as important as alloy because it sets the mechanical properties of the finished flange. It is stated on the order and on the mill test certificate, and it is not assumed from the alloy name alone.
| Alloy and temper | Strengthening | Density | Appendix L rating | Typical use |
|---|---|---|---|---|
| 6061-T6 | Heat treatable, 6xxx Mg2Si | 2.70 g/cm3 | Listed; ASTM B247 forging, rating basis ASME B31.3 Appendix L, value confirmed by the project designer | General pressure connections, nozzles and hubs |
| 3003-H112 | Non-heat-treatable, 3xxx strain hardened | 2.73 g/cm3 | Listed; rating basis ASME B31.3 Appendix L, value confirmed by the project designer | Low-pressure water and utility lines |
| 5083-H112 / H116 | Non-heat-treatable, 5xxx strain hardened | 2.66 g/cm3 | Outside Appendix L; rating calculated by the project designer under the applicable code | Marine, salt water and low-temperature service |
6061 is commonly supplied in T6. T651 and T652 are different tempers and are not interchangeable with T6; the state of the delivered flange follows the order and certificate. Strength values for 6061-T6 vary with product form, so the values used in design come from the mill test certificate for the lot and the design conditions. 5083 is strain hardened, and its temper is confirmed on the certificate. Alloy and temper outside these three are reviewed separately under the applicable code and export control process.
Welding and Fabrication of Aluminum Long Weld Neck Flanges
Aluminum welding differs from steel welding at the joint. AC GTAW is used to break up the oxide film, and filler selection follows the base alloy and service: ER4043 gives good crack resistance at lower strength, while ER5356 gives higher strength on 5xxx alloys and in marine service.
A 6061-T6 weld softens in the heat-affected zone towards an annealed or T4 condition, and joint strength falls against the parent metal. An as-welded joint is designed on heat-affected-zone strength. Restoring T6 after welding needs a full solution treatment, quench and artificial ageing, with distortion risk, so the usual design basis is the as-welded condition. Steel preheat and post-weld heat treatment parameters do not apply to aluminum. 5xxx alloys such as 5083 retain a higher share of strength across the weld zone, with allowable values confirmed under the design code.
Plate-cut flanges follow ASTM B209 and forged flanges follow ASTM B247/B247M or the corresponding ASME SB-247. The manufacturing route changes both inspection and rating basis, so state the expected route at inquiry.
Custom Drawing-Based Manufacturing of Aluminum Long Weld Neck Flanges
Hub length, bore and end form on an LWN are frequently decided by the equipment drawing, and a catalogue covers only part of that demand. Custom drawing-based manufacturing converts the dimensions, material temper and inspection requirements on the customer drawing into a part that can be made, inspected and traced. That conversion is the measure of a workshop's real capability on this flange type.
The drawing should state overall hub length H measured from the facing, hub outside diameter and wall thickness, bore size, end form (square cut, weld bevel or with a nut stop), facing (RF or FF), bolt holes and tolerances. Add the system in use (ASME Class or EN PN), mating flange information, service medium and temperature, and whether hub reinforcement needs checking.
The working sequence is drawing and service review, confirmation of alloy, temper and manufacturing route, review of dimensions and flange-end rating and hub reinforcement, forging and machining, dimensional and material inspection, marking and packing, and delivery. Records are kept at each step, especially the dimensional inspection record and the melt-lot mill certificate, so the received flange can be checked line by line against the drawing. Hub reinforcement and flange-end rating are separate checks; agree at drawing review which party performs each calculation.
Aluminum Long Weld Neck Flange Manufacturers: Qualification and Inspection
Qualifying long weld neck flange manufacturers rests on traceability, command of the standards and inspection records. Ask for an EN 10204 3.1 certificate matched to the melt and lot; 3.2 certification and third-party inspection can be arranged when the order calls for them. Ask for chemical and mechanical reports, dimensional records, surface and penetrant testing, and positive material identification.
| Inspection item | What it establishes |
|---|---|
| Chemical composition, mechanical properties, hardness | Alloy and temper match the order |
| Dimensional inspection | Hub length, bore and bolt holes match the drawing |
| Surface and penetrant testing (PT) | Surface breaking defects are found |
| Positive material identification (PMI) | Mixed material is excluded |
| EN 10204 3.1 / 3.2 | Material traceability to the lot |
| Third-party inspection | Arranged to the purchase order |
GNEE was established in 2008 and exports to more than 100 countries and regions. EN 10204 3.1 certification ships with the order, and 3.2 certificates and third-party inspection can be arranged.
Engineers reply within 24 hours during inquiry and drawing review.
Applications of Aluminum Long Weld Neck Flanges
The long hub suits nozzles that need the weld moved away from the gasket face and a stress transition into the shell. Typical positions are pressure vessel nozzles, column and tower nozzles, heat exchanger channel and shell connections, storage tank outlets, and instrument and level-gauge branches.
Aluminum is chosen on these positions for wet or coastal atmospheres, process media that attack carbon steel, low-temperature and cryogenic service, and assemblies where lifted weight matters. 6061-T6 covers general pressure connections, 3003-H112 suits low-pressure water and utility lines, and 5083 serves marine and low-temperature work, with the rating established for the selected alloy and temper.


Inspection and Testing of Aluminum Long Weld Neck Flange Orders
Each order is checked against the drawing and the purchase order. Chemical composition and mechanical properties are reported on the EN 10204 3.1 certificate for the melt and lot. Dimensional inspection records cover hub length, bore, flange-end values, bolt circle and facing. Surface examination and penetrant testing are applied to the flange and hub, and PMI excludes mixed material before packing.
Third-party inspection and EN 10204 3.2 certification are arranged when the purchase order specifies them. The packing list is keyed to the same line numbers as the inspection records so the delivered flange can be traced back to its lot.

Packaging of Aluminum Long Weld Neck Flanges
Flanges are packed in export crates with the facing protected against contact damage and the surfaces sealed against moisture and oxidation during sea freight. Each flange carries a mark with the alloy, temper, size, class and heat number. The packing list follows the inspection records line by line.


About GNEE
Established in 2008, exporting to more than 100 countries and regions.
Supply covers aluminum plate, sheet, coil, foil, bar, tube, profile, pipe fittings and flanges from one source.
In-house forging, CNC machining and cutting capability for drawing-based flange dimensions.
Export packing with protected facings and documentation keyed to the delivered lots.
Request a Quote for Aluminum Long Weld Neck Flanges
Include the alloy and temper, size and class, hub length and bore, facing, quantity, end form, and inspection and packing requirements.
MOQ is flexible, with small trial orders and full containers both accepted. Lead time is 15-30 days. EN 10204 3.1 certification ships with the order, and 3.2 and third-party inspection can be arranged. Pricing is anchored to SMM, trade terms are FOB and CIF, payment is by T/T or L/C, and we reply within 24 hours.
Send your drawing and service conditions for a quotation on an aluminum long weld neck flange.
FAQ
Q1: How does an aluminum LWN differ from a steel LWN in standards and service?
A: The flange ring dimensions of both follow ASME B16.5 tables, and the hub default rules come from section 2.8 of the same standard. The rating system is what differs. A steel LWN uses the B16.5 P-T tables, while an aluminum flange takes its pressure-temperature rating from ASME B31.3 Appendix L, with the European PN series in EN 1092-4. Steel pressure class figures and material group values do not transfer to an aluminum flange. Aluminum suits corrosion, weight saving, marine and low-temperature service, and the welded joint is designed on heat-affected-zone strength.
Q2: Which dimensions matter most on an aluminum long weld neck flange?
A: Dimensions fall into two groups: the flange end and the hub. The flange end covers outside diameter, thickness, bolt circle, bolt hole size and count, and facing. The hub covers overall length H, large-end and small-end outside diameters, wall thickness, bore B and end form. Check the flange end size and class first because they decide whether the flange mates, then the hub length and bore because they govern reinforcement and butt-weld match, and finally the facing and end form.
Q3: Can you manufacture a non-standard aluminum LWN from my drawing, and what should the drawing show?
A: Yes. Hub length, bore and end form are regular drawing-based requests. The drawing should give overall hub length H measured from the facing, hub outside diameter and wall thickness, bore size, end form, facing type (RF or FF), bolt holes and tolerances. Add the system in use, the mating flange, the service medium and temperature, and whether a hub reinforcement check is required. Those details shorten both quotation and technical confirmation.
Q4: Can ASME B16.5 dimensions be used for an aluminum long weld neck flange, and why can't the pressure rating be copied over?
A: The dimensional system can be used. ASME B16.5-2020 defines this flange type as a straight hub welding flange in section 2.8. The flange end, including outside diameter, thickness, facing, drilling and flange-end rating, follows the weld neck flange tables of the same size and class, and the hub follows the section 2.8 default rules or the equipment drawing and agreement. The pressure rating does not transfer because the B16.5 rating tables are written for the steel material groups it lists, and aluminum is outside them. The pressure-temperature rating of an aluminum flange comes from ASME B31.3 Appendix L, which covers specific grades and tempers such as 6061-T6 and 3003-H112, subject to confirmation by the project designer for the actual grade, temper and service conditions. A flange dimensioned to B16.5 does not carry a B16.5 rating. Section 2.8 gives default rules and no separate size table: equal-thickness straight hub, through-hub length of 229 mm up to NPS 4 and 305 mm above NPS 4, bore equal to the weld neck flange B dimension, and a square-cut end. Values outside the defaults follow the equipment drawing or agreement.
Q5: Besides 6061-T6, which aluminum grades and tempers are available, and how is the rating confirmed?
A: Grades are confirmed against the order and the mill test certificate. 3003-H112 has lower strength and good weldability, is common in low-pressure water and utility service, and appears in the Appendix L tables. 5083 is a non-heat-treatable 5xxx alloy with strong corrosion resistance for marine and low-temperature work, is supplied in H112 or H116 type tempers, and is outside the Appendix L tables, so its rating is calculated by the project designer under the applicable code. 6061 is commonly supplied in T6; T651 and T652 are different tempers and are not interchangeable. Temper and values follow the mill test certificate and the design conditions.
Q6: What is the MOQ and lead time for a custom aluminum LWN, and what does a quote need?
A: MOQ is flexible, with small trial orders and full containers both accepted. Lead time is 15 to 30 days, confirmed against the drawing and quantity. A quote needs the grade and temper, dimension drawing, flange class and system, facing, quantity, end form, and inspection and packing requirements. Pricing is anchored to SMM, trade terms are FOB and CIF, payment is T/T or L/C, and we reply within 24 hours of an inquiry.
Hot Tags: aluminum long weld neck flanges, China aluminum long weld neck flanges manufacturers